smartctl 6.5 2016-05-07 r4318 [x86_64-linux-4.11.3-unRAID] (local build) Copyright (C) 2002-16, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Model Family: Seagate Barracuda 7200.11 Device Model: ST3750330AS Serial Number: 3QK02LH2 LU WWN Device Id: 5 000c50 009a0d92a Firmware Version: SD04 User Capacity: 750,156,374,016 bytes [750 GB] Sector Size: 512 bytes logical/physical Rotation Rate: 7200 rpm Device is: In smartctl database [for details use: -P show] ATA Version is: ATA/ATAPI-7 (minor revision not indicated) Local Time is: Wed Jun 14 22:19:35 2017 PDT ==> WARNING: There are known problems with these drives, see the following Seagate web pages: http://knowledge.seagate.com/articles/en_US/FAQ/207931en http://knowledge.seagate.com/articles/en_US/FAQ/207951en http://knowledge.seagate.com/articles/en_US/FAQ/207957en SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED See vendor-specific Attribute list for marginal Attributes. General SMART Values: Offline data collection status: (0x82) Offline data collection activity was completed without error. Auto Offline Data Collection: Enabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 634) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 159) minutes. Conveyance self-test routine recommended polling time: ( 2) minutes. SCT capabilities: (0x003b) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 10 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000f 114 099 006 Pre-fail Always - 79768949 3 Spin_Up_Time 0x0003 093 090 000 Pre-fail Always - 0 4 Start_Stop_Count 0x0032 100 100 020 Old_age Always - 343 5 Reallocated_Sector_Ct 0x0033 100 100 036 Pre-fail Always - 15 7 Seek_Error_Rate 0x000f 049 047 030 Pre-fail Always - 1494676007168 9 Power_On_Hours 0x0032 087 087 000 Old_age Always - 11542 10 Spin_Retry_Count 0x0013 100 100 097 Pre-fail Always - 7 12 Power_Cycle_Count 0x0032 100 037 020 Old_age Always - 194 184 End-to-End_Error 0x0032 100 100 099 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 0 188 Command_Timeout 0x0032 100 098 000 Old_age Always - 5 189 High_Fly_Writes 0x003a 013 013 000 Old_age Always - 87 190 Airflow_Temperature_Cel 0x0022 064 028 045 Old_age Always In_the_past 36 (0 217 36 35 0) 194 Temperature_Celsius 0x0022 036 072 000 Old_age Always - 36 (0 17 0 0 0) 195 Hardware_ECC_Recovered 0x001a 045 012 000 Old_age Always - 79768949 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 200 200 000 Old_age Always - 3 SMART Error Log Version: 1 No Errors Logged SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Completed without error 00% 11542 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.